All parameters are from MECO official product specifications and catalog, for selection and training reference.








| Model | Battery | PV Input Voltage | PV Max Power | PV Max Current | AC Input Range | AC Charge Power | AC Rated Output | AC Output Range | Efficiency | AC Bypass |
|---|---|---|---|---|---|---|---|---|---|---|
| MECO 320Wh 100W | 320 Wh | 12–30 V | 100 W | ≤5 A | — | — | USB / DC output only | — | — | — |
| MECO 1kWh 300W | ~1.0 kWh | 12–60 V | 220 W | ≤11 A | 90–280 V | 350 W | 300 W / 300 VA | 220–240 V | ≥85% | 3 A · ≈660 W (220 V) |
| MECO 1kWh Pro 500W | ~1.0 kWh | 12–60 V | 500 W | ≤18 A | 90–280 V | 500 W | 500 W / 500 VA | 220–240 V | ≥87% | 5 A · ≈1100 W (220 V) |
| MECO 1.8kWh Lite 600W | ~1.8 kWh | 12–60 V | 600 W | ≤20 A | 90–280 V | 600 W | 600 W / 600 VA | 220–240 V | — | 5 A · ≈1100 W (220 V) |
| MECO 2kWh 1200W | ~2.0 kWh | 12–60 V | 600 W | ≤20 A | 90–280 V | 1200 W | 1200 W / 1200 VA | 220–240 V | 90% | 10 A · ≈2200 W (220 V) |
| MECO 4kWh 1200W | ~4.0 kWh | 12–60 V | 800 W | ≤20 A | 90–280 V | 1200 W | 1200 W / 1200 VA | 220–240 V | — | — |
| MECO 4kWh Pro 2200W | ~4.0 kWh | 60–450 V | 4000 W | ≤20 A | 90–280 V | 2200 W | 2200 W / 2200 VA | 220–240 V | 93% | 10 A · ≈2200 W (220 V) |
| MECO 3.6kWh Pro 3000W | ~3.6 kWh | 60–450 V | 4000 W | ≤20 A | 90–280 V | 2200 W | 3000 W / 3000 VA | 220–240 V | 92% | 10 A · ≈2200 W (220 V) |
| MECO 5.4kWh 5000W | ~5.4 kWh | 60–450 V | 6000 W | ≤20 A | 90–280 V | 2200 W mains / 5000 W generator | 5000 W / 5000 VA | 220–240 V | 92% | 10 A · ≈2200 W (220 V) |
All inverter models output 50/60 Hz pure sine wave; AC output voltage 220–240 V adjustable. 320Wh is DC-only (USB/DC5521), no AC. MPPT: 1kWh series / 1.8kWh Lite / 2kWh / 4kWh(1200W) low-voltage 12–60 V (2kWh 16–51 V); 4kWh Pro / 3.6kWh Pro / 5.4kWh high-voltage 60–450 V. "—" = not stated in the catalog.
In bypass (EPS) mode, mains feeds loads directly. Overload thresholds and protection times are from each model's bi-directional inverter specification; "long" = continuous operation, "—" = not specified.
| Model | Bypass rated current | Bypass rated power | Overload 110% | Overload 120% | Overload 150% | Overload 200% |
|---|---|---|---|---|---|---|
| MECO 320Wh 100W | — | — | — | — | — | — |
| MECO 1kWh 300W | 3 A | ≈660 W | 3.3 A · continuous | 3.6 A · 125±10 s | 4.5 A · 20±2 s | 6 A · 5±1 s |
| MECO 1kWh Pro 500W | 5 A | ≈1100 W | 5.5 A · continuous | 6 A · 125±10 s | 7.5 A · 20±4 s | 10 A · 5±2 s |
| MECO 1.8kWh Lite 600W | 5 A | ≈1100 W | 5.5 A · continuous | 6 A · 125±10 s | 7.5 A · 20±2 s | 10 A · 5±1 s |
| MECO 2kWh 1200W | 10 A | ≈2200 W | 11 A · continuous | 12 A · 125±10 s | 15 A · 20±2 s | 20 A · 5±2 s |
| MECO 4kWh 1200W | — | — | — | — | — | — |
| MECO 4kWh Pro 2200W | 10 A | ≈2200 W | 11 A · continuous | 12 A · 125±10 s | 15 A · 20±2 s | 20 A · 5±1 s |
| MECO 3.6kWh Pro 3000W | 10 A | ≈2200 W | 11 A · continuous | 12 A · 125±10 s | 15 A · 20±2 s | 20 A · 5±1 s |
| MECO 5.4kWh 5000W | 10 A | ≈2200 W | 11 A · continuous | 12 A · 125±10 s | 15 A · 20±5 s | 20 A · 5±2 s |
Overload protection applies to bypass output current: beyond the rated current, protection trips per the threshold and time of the matching level (~125 s at 120%, ~20 s at 150%, ~5 s at 200%). Source: MGI series bi-directional inverter specification (Megmeet). 320Wh has no AC in/out and no bypass; 4kWh (1200W) bypass not specified in the brochure.
Per-unit parameters for training and sales reference. Overload protection is momentary; the unit switches to constant power mode after overload.




Using 580W and 620W panels as examples, recommended panel counts and wiring are given per model. Recommendations are based on real output: solar panels typically generate only 60%–80% of nameplate (sun angle, heat, dust, clouds), so size up, not down, keeping actual charging close to each model's PV input limit. High-voltage models (4kWh Pro and up) have a 20A MPPT: the series limit is 8 panels (above 9, open-circuit voltage approaches the 450V cap), so filling the limit needs parallel - 12 panels (6S2P) for 4kWh Pro / 3.6kWh Pro, 16 panels (8S2P) for 5.4kWh. Low-voltage models: one panel direct or two in parallel.
| Parameter | 620W panel (measured) | 580W panel (reference) |
|---|---|---|
| Max power Pmax | 620 W | 580 W |
| Operating voltage Vmp | 40.82 V | ~42 V (estimate) |
| Operating current Imp | 15.19 A | ~13.8 A (estimate) |
| Open-circuit voltage Voc | 48.10 V | ~49.5 V (estimate) |
| Short-circuit current Isc | 16.06 A | ~15.5 A (estimate) |
| Module efficiency | 23% | — |
| Panel | Theoretical daily (STC 5h) | Actual daily (typical) |
|---|---|---|
| 620W Panel | 620 W panel ≈3.1 kWh/day | ≈1.9–2.5 kWh/day |
| 580W Panel | 580 W panel ≈2.9 kWh/day | ≈1.7–2.3 kWh/day |
Estimated at 5h peak sun per day; actual output varies with weather, angle, temperature and dust — verify on site.
| Model | With 580W panels | With 620W panels | Wiring | Theoretical (STC, sunny) | Real-world (typical weather) | Notes |
|---|---|---|---|---|---|---|
| 320Wh (100W) | Not suitable | Not suitable | — | — | — | PV input 12–30 V / 100 W; only for small panels ≤ 100 W |
| 1kWh (300W) | Not recommended | Not recommended | — | — | — | PV input limited to 11 A; large panels are wasted. Use one 100–200 W panel instead. |
| 1kWh Pro (500W) | 1 panel | 1 panel | Single panel | ≈580–620 W | ≈350–500 W | Single-panel voltage 42/40.8V is within 12–60V; PV max charge 500W. Two panels in parallel would exceed the 18A limit with no gain above the 500W cap - one panel is enough. |
| 1.8kWh Lite (600W) | 2 in parallel | 2 in parallel | Parallel (Y-cable) | ≈1160–1240 W | ≈600 W | PV input 12–60V / 600W / ≤20A; two panels in parallel keep ≈40V, current adds up over the 20A clip (harmless), real charging approaches 600W. On a budget one panel works (≈350–500W). Never in series (≈80V over 60V). |
| 2kWh (1200W) | 2 in parallel | 2 in parallel | Parallel (Y-cable) | ≈1160–1240 W | ≈600 W | PV input 12–60V / 600W / ≤20A; two panels in parallel keep ≈40V while current adds up (≈28–30A) - anything above 20A is clipped (harmless), real charging approaches 600W. On a budget one panel works (≈350–500W). Never in series (≈80V over 60V). |
| 4kWh (1200W) | 2 in parallel | 2 in parallel | Parallel (Y-cable) | ≈1160–1240 W | ≈700–800 W | PV input 12–60V / 800W / ≤20A; two panels in parallel keep voltage ≈40V while current adds up (≈28–30A) - the unit clips anything above 20A (harmless) and charges close to 800W. Never connect in series (≈80V over the 60V limit). |
| 4kWh Pro (2200W) | 12 (6S2P) | 12 (6S2P) | 6S2P (6 series, 2 parallel) | ≈5040 W (20A limited) | ≈3000–4000 W | Recommended: 12 panels in 6S2P (6 in series, 2 in parallel) - 6×580W Vmp 252V or 6×620W Vmp 245V; after the 20A clip this gives ≈5040W/4900W, limited to the full 4000W cap - steady 4000W charging on sunny days and more than 8-in-series on cloudy days. 20A is the MPPT limit - parallel is safe (use 30A-rated MC4/cables); above 9 panels in pure series Voc approaches 450V (cold-weather risk), so extra capacity must be in parallel. On a budget: 10 panels (5S2P) also fill 4000W on sunny days. |
| 3.6kWh Pro (3000W) | 12 (6S2P) | 12 (6S2P) | 6S2P (6 series, 2 parallel) | ≈5040 W (20A limited) | ≈3000–4000 W | Recommended: 12 panels in 6S2P (6 in series, 2 in parallel) - 6×580W Vmp 252V or 6×620W Vmp 245V; after the 20A clip this gives ≈5040W/4900W, limited to the full 4000W cap - steady 4000W charging on sunny days and more than 8-in-series on cloudy days. 20A is the MPPT limit - parallel is safe (use 30A-rated MC4/cables); above 9 panels in pure series Voc approaches 450V (cold-weather risk), so extra capacity must be in parallel. On a budget: 10 panels (5S2P) also fill 4000W on sunny days. |
| 5.4kWh (5000W) | 16 (8S2P) | 16 (8S2P) | 8S2P (8 series, 2 parallel) | ≈6720 W (20A limited) | ≈2700–6000 W | Recommended: 16 panels in 8S2P (8 in series, 2 in parallel) - 8×580W Vmp 336V or 8×620W Vmp 327V; after the 20A clip this gives ≈6720W/6540W, limited to the full 6000W cap (verified: above 300V, 20A ≈ 6000W). 12 panels (6S2P) only reach ≈5040W - not enough. 20A is the MPPT limit - parallel is safe (use 30A-rated MC4/cables); above 9 panels in pure series Voc approaches 450V (cold-weather risk), so extra capacity must be in parallel. |
Real output is usually only 60%–80% of the rated value (clear midday ≈70%, daily average 60–70%, cloudy/rainy 30–50%) due to sun angle, heat and dust. Size panels up, not down, and wipe the panels regularly.
Series: connect the red positive (+) of one panel to the black negative (–) of the next, chaining them one by one. Voltage adds up (2×40V panels ≈ 80V), current stays the same. Good for high-voltage inputs, but total voltage must not exceed the unit's PV input limit.
Parallel: connect all positive (+) leads together and all negative (–) leads together (use a Y-cable). Voltage stays the same (≈40V), current adds up. Safe for low-voltage inputs – the only safe way to add more panels on low-voltage models.
Reference figures based on typical device power, consumption factor (real running power) and surge factor. Appliances with compressors or motors (fridge, AC, pump, washer) draw several times their running current at start-up - stagger start-ups and check each device's surge fits the model.
Consumption factor × rated power = real running power (e.g. inverter AC ≈ 50%). Surge factor matters at start-up. Daily energy = real power × hours. Figures are typical - always check device nameplates.
Runtime calculated on rated battery capacity (same basis as the catalog); usable energy is about 80–90% (protection margin). For small models, check AC output first, then runtime. Do not start several large appliances at once.
Figures are estimates: devices used together and total power kept within rated output. Always check the device nameplate; do not start several motor-type appliances at once.