Buy NowOfficial products · Local support
Buy Now
Product Overview

Nine models, one clear table

All parameters are from MECO official product specifications and catalog, for selection and training reference.

MECO 1kWh · 300W
MECO 1kWh · 300W
MECO 1kWh Pro · 500W
MECO 1kWh Pro · 500W
MECO 1.8kWh Lite · 600W
MECO 1.8kWh Lite · 600W
MECO 2kWh · 1200W
MECO 2kWh · 1200W
MECO 4kWh · 1200W
MECO 4kWh · 1200W
MECO 4kWh Pro · 2200W
MECO 4kWh Pro · 2200W
MECO 3.6kWh Pro · 3000W
MECO 3.6kWh Pro · 3000W
MECO 5.4kWh · 5000W
MECO 5.4kWh · 5000W
ModelBattery PV Input VoltagePV Max PowerPV Max Current AC Input RangeAC Charge Power AC Rated OutputAC Output RangeEfficiencyAC Bypass
MECO 320Wh
100W
320 Wh12–30 V100 W≤5 A——USB / DC output only———
MECO 1kWh
300W
~1.0 kWh12–60 V220 W≤11 A90–280 V350 W300 W / 300 VA220–240 V≥85%3 A · ≈660 W (220 V)
MECO 1kWh Pro
500W
~1.0 kWh12–60 V500 W≤18 A90–280 V500 W500 W / 500 VA220–240 V≥87%5 A · ≈1100 W (220 V)
MECO 1.8kWh Lite
600W
~1.8 kWh12–60 V600 W≤20 A90–280 V600 W600 W / 600 VA220–240 V—5 A · ≈1100 W (220 V)
MECO 2kWh
1200W
~2.0 kWh12–60 V600 W≤20 A90–280 V1200 W1200 W / 1200 VA220–240 V90%10 A · ≈2200 W (220 V)
MECO 4kWh
1200W
~4.0 kWh12–60 V800 W≤20 A90–280 V1200 W1200 W / 1200 VA220–240 V——
MECO 4kWh Pro
2200W
~4.0 kWh60–450 V4000 W≤20 A90–280 V2200 W2200 W / 2200 VA220–240 V93%10 A · ≈2200 W (220 V)
MECO 3.6kWh Pro
3000W
~3.6 kWh60–450 V4000 W≤20 A90–280 V2200 W3000 W / 3000 VA220–240 V92%10 A · ≈2200 W (220 V)
MECO 5.4kWh
5000W
~5.4 kWh60–450 V6000 W≤20 A90–280 V2200 W mains / 5000 W generator5000 W / 5000 VA220–240 V92%10 A · ≈2200 W (220 V)

All inverter models output 50/60 Hz pure sine wave; AC output voltage 220–240 V adjustable. 320Wh is DC-only (USB/DC5521), no AC. MPPT: 1kWh series / 1.8kWh Lite / 2kWh / 4kWh(1200W) low-voltage 12–60 V (2kWh 16–51 V); 4kWh Pro / 3.6kWh Pro / 5.4kWh high-voltage 60–450 V. "—" = not stated in the catalog.

AC Bypass Output Specification (EPS pass-through)

In bypass (EPS) mode, mains feeds loads directly. Overload thresholds and protection times are from each model's bi-directional inverter specification; "long" = continuous operation, "—" = not specified.

Model Bypass rated current Bypass rated power Overload 110% Overload 120% Overload 150% Overload 200%
MECO 320Wh 100W——————
MECO 1kWh 300W3 A≈660 W3.3 A · continuous3.6 A · 125±10 s4.5 A · 20±2 s6 A · 5±1 s
MECO 1kWh Pro 500W5 A≈1100 W5.5 A · continuous6 A · 125±10 s7.5 A · 20±4 s10 A · 5±2 s
MECO 1.8kWh Lite 600W5 A≈1100 W5.5 A · continuous6 A · 125±10 s7.5 A · 20±2 s10 A · 5±1 s
MECO 2kWh 1200W10 A≈2200 W11 A · continuous12 A · 125±10 s15 A · 20±2 s20 A · 5±2 s
MECO 4kWh 1200W——————
MECO 4kWh Pro 2200W10 A≈2200 W11 A · continuous12 A · 125±10 s15 A · 20±2 s20 A · 5±1 s
MECO 3.6kWh Pro 3000W10 A≈2200 W11 A · continuous12 A · 125±10 s15 A · 20±2 s20 A · 5±1 s
MECO 5.4kWh 5000W10 A≈2200 W11 A · continuous12 A · 125±10 s15 A · 20±5 s20 A · 5±2 s

Overload protection applies to bypass output current: beyond the rated current, protection trips per the threshold and time of the matching level (~125 s at 120%, ~20 s at 150%, ~5 s at 200%). Source: MGI series bi-directional inverter specification (Megmeet). 320Wh has no AC in/out and no bypass; 4kWh (1200W) bypass not specified in the brochure.

Model Details

Key parameters of each model

Per-unit parameters for training and sales reference. Overload protection is momentary; the unit switches to constant power mode after overload.

System Configurator Guide

How to set up solar panels?

Using 580W and 620W panels as examples, recommended panel counts and wiring are given per model. Recommendations are based on real output: solar panels typically generate only 60%–80% of nameplate (sun angle, heat, dust, clouds), so size up, not down, keeping actual charging close to each model's PV input limit. High-voltage models (4kWh Pro and up) have a 20A MPPT: the series limit is 8 panels (above 9, open-circuit voltage approaches the 450V cap), so filling the limit needs parallel - 12 panels (6S2P) for 4kWh Pro / 3.6kWh Pro, 16 panels (8S2P) for 5.4kWh. Low-voltage models: one panel direct or two in parallel.

Comparison of the two panels
Parameter620W panel (measured)580W panel (reference)
Max power Pmax620 W580 W
Operating voltage Vmp40.82 V~42 V (estimate)
Operating current Imp15.19 A~13.8 A (estimate)
Open-circuit voltage Voc48.10 V~49.5 V (estimate)
Short-circuit current Isc16.06 A~15.5 A (estimate)
Module efficiency23%—
580W panel parameters are estimated from common market models; always check the actual panel nameplate.

Solar panel daily yield (theoretical vs actual)

PanelTheoretical daily (STC 5h)Actual daily (typical)
620W Panel620 W panel ≈3.1 kWh/day≈1.9–2.5 kWh/day
580W Panel580 W panel ≈2.9 kWh/day≈1.7–2.3 kWh/day

Estimated at 5h peak sun per day; actual output varies with weather, angle, temperature and dust — verify on site.

ModelWith 580W panelsWith 620W panelsWiringTheoretical (STC, sunny)Real-world (typical weather)Notes
320Wh (100W)Not suitableNot suitable———PV input 12–30 V / 100 W; only for small panels ≤ 100 W
1kWh (300W)Not recommendedNot recommended———PV input limited to 11 A; large panels are wasted. Use one 100–200 W panel instead.
1kWh Pro (500W)1 panel1 panelSingle panel≈580–620 W≈350–500 WSingle-panel voltage 42/40.8V is within 12–60V; PV max charge 500W. Two panels in parallel would exceed the 18A limit with no gain above the 500W cap - one panel is enough.
1.8kWh Lite (600W)2 in parallel2 in parallelParallel (Y-cable)≈1160–1240 W≈600 WPV input 12–60V / 600W / ≤20A; two panels in parallel keep ≈40V, current adds up over the 20A clip (harmless), real charging approaches 600W. On a budget one panel works (≈350–500W). Never in series (≈80V over 60V).
2kWh (1200W)2 in parallel2 in parallelParallel (Y-cable)≈1160–1240 W≈600 WPV input 12–60V / 600W / ≤20A; two panels in parallel keep ≈40V while current adds up (≈28–30A) - anything above 20A is clipped (harmless), real charging approaches 600W. On a budget one panel works (≈350–500W). Never in series (≈80V over 60V).
4kWh (1200W)2 in parallel2 in parallelParallel (Y-cable)≈1160–1240 W≈700–800 WPV input 12–60V / 800W / ≤20A; two panels in parallel keep voltage ≈40V while current adds up (≈28–30A) - the unit clips anything above 20A (harmless) and charges close to 800W. Never connect in series (≈80V over the 60V limit).
4kWh Pro (2200W)12 (6S2P)12 (6S2P)6S2P (6 series, 2 parallel)≈5040 W (20A limited)≈3000–4000 WRecommended: 12 panels in 6S2P (6 in series, 2 in parallel) - 6×580W Vmp 252V or 6×620W Vmp 245V; after the 20A clip this gives ≈5040W/4900W, limited to the full 4000W cap - steady 4000W charging on sunny days and more than 8-in-series on cloudy days. 20A is the MPPT limit - parallel is safe (use 30A-rated MC4/cables); above 9 panels in pure series Voc approaches 450V (cold-weather risk), so extra capacity must be in parallel. On a budget: 10 panels (5S2P) also fill 4000W on sunny days.
3.6kWh Pro (3000W)12 (6S2P)12 (6S2P)6S2P (6 series, 2 parallel)≈5040 W (20A limited)≈3000–4000 WRecommended: 12 panels in 6S2P (6 in series, 2 in parallel) - 6×580W Vmp 252V or 6×620W Vmp 245V; after the 20A clip this gives ≈5040W/4900W, limited to the full 4000W cap - steady 4000W charging on sunny days and more than 8-in-series on cloudy days. 20A is the MPPT limit - parallel is safe (use 30A-rated MC4/cables); above 9 panels in pure series Voc approaches 450V (cold-weather risk), so extra capacity must be in parallel. On a budget: 10 panels (5S2P) also fill 4000W on sunny days.
5.4kWh (5000W)16 (8S2P)16 (8S2P)8S2P (8 series, 2 parallel)≈6720 W (20A limited)≈2700–6000 WRecommended: 16 panels in 8S2P (8 in series, 2 in parallel) - 8×580W Vmp 336V or 8×620W Vmp 327V; after the 20A clip this gives ≈6720W/6540W, limited to the full 6000W cap (verified: above 300V, 20A ≈ 6000W). 12 panels (6S2P) only reach ≈5040W - not enough. 20A is the MPPT limit - parallel is safe (use 30A-rated MC4/cables); above 9 panels in pure series Voc approaches 450V (cold-weather risk), so extra capacity must be in parallel.

Real output is usually only 60%–80% of the rated value (clear midday ≈70%, daily average 60–70%, cloudy/rainy 30–50%) due to sun angle, heat and dust. Size panels up, not down, and wipe the panels regularly.

Series vs Parallel Connection
Series vs Parallel – how to connect (see diagram)

Series: connect the red positive (+) of one panel to the black negative (–) of the next, chaining them one by one. Voltage adds up (2×40V panels ≈ 80V), current stays the same. Good for high-voltage inputs, but total voltage must not exceed the unit's PV input limit.

Parallel: connect all positive (+) leads together and all negative (–) leads together (use a Y-cable). Voltage stays the same (≈40V), current adds up. Safe for low-voltage inputs – the only safe way to add more panels on low-voltage models.

Load Calculator Reference

What devices can it run?

Reference figures based on typical device power, consumption factor (real running power) and surge factor. Appliances with compressors or motors (fridge, AC, pump, washer) draw several times their running current at start-up - stagger start-ups and check each device's surge fits the model.

① Appliance power usage reference

Consumption factor × rated power = real running power (e.g. inverter AC ≈ 50%). Surge factor matters at start-up. Daily energy = real power × hours. Figures are typical - always check device nameplates.

② What each model can run & runtime

Runtime calculated on rated battery capacity (same basis as the catalog); usable energy is about 80–90% (protection margin). For small models, check AC output first, then runtime. Do not start several large appliances at once.

Figures are estimates: devices used together and total power kept within rated output. Always check the device nameplate; do not start several motor-type appliances at once.